How to Solve :
Oracle database error code ORA-28667 – USING INDEX option not allowed for the primary key of an IOT
Oracle Database Error Code ORA-28667 Description :
USING INDEX option not allowed for the primary key of an IOT
Error Cause:
User attempted to define storage attributes for the primary key index of an Index-Organized table with USING INDEX clause. All the storage attribute defined for the (IOT)table applies to the primary key index and a separate USING INDEX clause is not required.
How to Solve :
Remove the USING INDEX clause and specify all attributes directly for the table
Filed under: How to Solve, Oracle 10g, Oracle 11g, Oracle 9i, Oracle Error Codes Etiketler: ora - 28667, 28667, about oracle ORA-28667 error, help ORA-28667 about, ORA-28667 error code, ORA-28667 problem, Oracle 9i 10g 11g, Oracle Database Server Error Messages, Oracle Error Codes, oracle number 28667 error code, oracle ORA-28667 example, USING INDEX option not allowed for the primary key of an IOT
No Comment Yet
No Comment Yet
Recent Entries
- Oracle database error code ORA-29959 – error in the execution of the string routine for one or more of the index partitions
- Oracle database error code ORA-31601 – Function string cannot be called now that fetch has begun.
- Oracle database error code ORA-29958 – fatal error occurred in the execution of ODCIINDEXCREATE routine
- Oracle database error code ORA-31600 – invalid input value string for parameter string in function string
- Oracle database error code ORA-29957 – cannot create a function-based domain index on a string table
- Oracle database error code ORA-31604 – invalid string parameter “string” for object type string in function string
- Oracle database error code ORA-29961 – too many warnings occurred in the execution of ODCIIndex DDL routine
Search Oracle Error Codes and Descriptions:
Be The First To Comment
Similar Errors
Please Leave Your Comments Below